5 changes: 5 additions & 0 deletions .changeset/c5-frozen-site-meter-stale.md
Original file line number Diff line number Diff line change
@@ -0,0 +1,5 @@
---
"ftw": patch
---

Treat a site meter that repeats one reading as stale. When FTW moves its own batteries and chargers by more than 500 W in sum, the devices' own readings follow, and the meter's total and phase values still stay the same for 30 s and 3 polls after that, FTW stops dispatch, returns devices to their own control and raises no EV, as for a silent meter. From the first such repeat, battery dispatch treats the reading as held, as it does for a reading with an old timestamp: it holds the battery instead of acting on the same error again. This also holds for a meter frozen since FTW started and for a car plugged in during the freeze. A quiet site is never marked stale, nor is a meter that sends a new reading only every 10 s and loses one, nor are moves that cancel out at the meter, and the first changed reading reopens dispatch. Before, such a meter counted as fresh because each poll brought a new timestamp, and in a rig run the battery swung from +5 kW to -5 kW on 40 s of repeated data. An EV order counts only once the charger reports the car drawing it, so at a site with no battery a frozen meter is found 30 s after that, not sooner.
11 changes: 5 additions & 6 deletions go/cmd/ftw/main.go
Original file line number Diff line number Diff line change
Expand Up @@ -2612,7 +2612,10 @@ func main() {
if timeout <= 0 {
timeout = 60 * time.Second
}
if gate := evaluateSiteDispatchFreshnessAt(tel, meter, candidate.Fuse.MaxAmps, candidate.Fuse.Phases, timeout, time.Now()); !gate.Allowed() {
ctrlMu.Lock()
gate := siteMeterGateLocked(tel, ctrl, meter, candidate.Fuse.MaxAmps, candidate.Fuse.Phases, timeout, time.Now())
ctrlMu.Unlock()
if !gate.Allowed() {
return fmt.Errorf("measure before enabling control: %s", gate.Reason)
}
return nil
Expand Down Expand Up @@ -3050,15 +3053,11 @@ func main() {
// standdown/default commands remain permitted.
ctrlMu.Lock()
ctrl.ObserveSiteImport(tel)
freshness := siteDispatchGateLocked(tel, ctrl, watchdogTimeout, tickNow)
siteMeterDriver := ctrl.SiteMeterDriver
siteFuseAmps := ctrl.SiteFuseAmps
siteFusePhases := ctrl.SiteFusePhases
forecastIntent := forecastCurtailmentActive(ctrl, tickNow)
ctrlMu.Unlock()
forecastCurtail.ObserveIntent(forecastIntent)
freshness := evaluateSiteDispatchFreshnessAt(
tel, siteMeterDriver, siteFuseAmps, siteFusePhases, watchdogTimeout, tickNow,
)
if reason := setupRuntimeBlockReason(); reason != "" {
freshness.Reason = reason
}
Expand Down
47 changes: 42 additions & 5 deletions go/cmd/ftw/site_dispatch_safety.go
Original file line number Diff line number Diff line change
Expand Up @@ -24,6 +24,16 @@ type siteDispatchDecision struct {

func (d siteDispatchDecision) Allowed() bool { return d.Reason == siteDispatchReady }

// frozenMeter closes the gate when the site meter repeats one reading while
// FTW's orders moved (control.State.ObserveSiteMeterFreeze). Such a meter
// answers every poll, so its UpdatedAt alone looks fresh.
func (d siteDispatchDecision) frozenMeter(frozen bool) siteDispatchDecision {
if frozen && d.Allowed() {
d.Reason = siteDispatchMeterStale
}
return d
}

// evaluateSiteDispatchFreshnessAt rejects physical dispatch when the site
// meter itself is stale. Per-phase currents are optional until the configured
// meter has emitted at least one of them; once available, every configured
Expand Down Expand Up @@ -71,11 +81,38 @@ func siteDispatchNow(
timeout = 60 * time.Second
}
ctrlMu.Lock()
siteMeter := ctrl.SiteMeterDriver
fuseAmps := ctrl.SiteFuseAmps
phases := ctrl.SiteFusePhases
ctrlMu.Unlock()
return evaluateSiteDispatchFreshnessAt(tel, siteMeter, fuseAmps, phases, timeout, now)
defer ctrlMu.Unlock()
return siteDispatchGateLocked(tel, ctrl, timeout, now)
}

// siteDispatchGateLocked is the pre-dispatch verdict the tick and
// siteDispatchNow share: the site meter's age and phase currents, and
// whether it repeats one reading while FTW's devices move. Call it with
// ctrlMu held.
func siteDispatchGateLocked(
tel *telemetry.Store,
ctrl *control.State,
timeout time.Duration,
now time.Time,
) siteDispatchDecision {
return siteMeterGateLocked(tel, ctrl, ctrl.SiteMeterDriver, ctrl.SiteFuseAmps, ctrl.SiteFusePhases, timeout, now)
}

// siteMeterGateLocked is siteDispatchGateLocked for a given meter and fuse.
// Setup uses it to judge a candidate's fuse before it enables control. Only
// the running site meter can be frozen. Call it with ctrlMu held.
func siteMeterGateLocked(
tel *telemetry.Store,
ctrl *control.State,
meter string,
fuseAmps float64,
phases int,
timeout time.Duration,
now time.Time,
) siteDispatchDecision {
ctrl.ObserveSiteMeterFreeze(tel, now)
frozen := meter == ctrl.SiteMeterDriver && ctrl.SiteMeterFrozen()
return evaluateSiteDispatchFreshnessAt(tel, meter, fuseAmps, phases, timeout, now).frozenMeter(frozen)
}

// sitePhaseCurrentsAt returns the configured phases in L1/L2/L3 order.
Expand Down
72 changes: 72 additions & 0 deletions go/cmd/ftw/site_meter_stale_test.go
Original file line number Diff line number Diff line change
Expand Up @@ -92,6 +92,78 @@ func TestEvaluateSiteDispatchFreshnessAllowsMeterWithoutPhaseTelemetry(t *testin
}
}

// A frozen site meter (control.State.SiteMeterFrozen) closes the gate as a
// stale meter, and leaves an already closed gate's reason alone.
func TestFrozenSiteMeterClosesDispatchGate(t *testing.T) {
tel := telemetry.NewStore()
tel.Update("meter", telemetry.DerMeter, 2667, nil, nil)
open := evaluateSiteDispatchFreshnessAt(tel, "meter", 0, 3, time.Minute, time.Now())
if !open.Allowed() {
t.Fatalf("fresh meter blocked: %q", open.Reason)
}
if got := open.frozenMeter(false); !got.Allowed() {
t.Fatalf("meter that is not frozen blocked: %q", got.Reason)
}
if got := open.frozenMeter(true); got.Reason != siteDispatchMeterStale {
t.Fatalf("frozen meter reason = %q, want %q", got.Reason, siteDispatchMeterStale)
}
phases := siteDispatchDecision{Reason: siteDispatchPhaseCurrentsStale}
if got := phases.frozenMeter(true); got.Reason != siteDispatchPhaseCurrentsStale {
t.Fatalf("frozen meter replaced reason %q with %q", siteDispatchPhaseCurrentsStale, got.Reason)
}
}

// The gate the tick and operator setpoints share watches the meter itself:
// one repeated sample (seed 207537) while FTW winds the battery 3 kW closes
// it as site_meter_stale, which sends drivers to default and chargers to
// 0 W, before the rig's EV rise at 38 s. A changed value reopens it.
func TestSiteDispatchGateClosesOnFrozenMeter(t *testing.T) {
tel := telemetry.NewStore()
cfg := &config.Config{Site: config.Site{WatchdogTimeoutS: 120}}
ctrl := control.NewState(0, 50, "meter")
cfgMu, ctrlMu := &sync.RWMutex{}, &sync.Mutex{}
frozen := []byte(`{"w":2667,"l1_a":2.4,"l2_a":5.5,"l3_a":-0.2,"l1_v":230,"l2_v":230,"l3_v":230}`)
soc := 0.5
tel.Update("bat", telemetry.DerBattery, 0, &soc, nil)
tel.EnsureDriverHealth("meter")
tel.EnsureDriverHealth("bat")

start := time.Now()
staleAt := -1
for s := 0; s <= 40; s++ {
if s == 2 { // FTW's order, and the battery follows it
ctrl.PrevTargets["bat"] = -3000
tel.Update("bat", telemetry.DerBattery, -3000, &soc, nil)
}
tel.Update("meter", telemetry.DerMeter, 2667, nil, frozen)
got := siteDispatchNow(tel, cfg, cfgMu, ctrl, ctrlMu, start.Add(time.Duration(s)*time.Second))
if !got.Allowed() {
if got.Reason != siteDispatchMeterStale {
t.Fatalf("frozen meter reason = %q, want %q", got.Reason, siteDispatchMeterStale)
}
staleAt = s
break
}
}
if staleAt < 0 || staleAt >= 38 {
t.Fatalf("meter repeated one sample for 40 s while the battery moved 3 kW: stale at %d s, want before 38 s", staleAt)
}

// Setup's check before it enables control, with the candidate's own
// fuse, sees the same verdict.
ctrlMu.Lock()
setup := siteMeterGateLocked(tel, ctrl, "meter", 25, 3, 2*time.Minute, start.Add(40*time.Second))
ctrlMu.Unlock()
if setup.Reason != siteDispatchMeterStale {
t.Fatalf("setup gate on a frozen meter = %q, want %q", setup.Reason, siteDispatchMeterStale)
}

tel.Update("meter", telemetry.DerMeter, 2654, nil, nil)
if got := siteDispatchNow(tel, cfg, cfgMu, ctrl, ctrlMu, start.Add(41*time.Second)); !got.Allowed() {
t.Fatalf("meter moving again stayed blocked: %q", got.Reason)
}
}

func TestStaleSiteDefaultTrackerIncludesOwnerOnceAndRearmsOnRecovery(t *testing.T) {
var tracker staleSiteDefaultTracker
names := []string{"ferroamp", "sungrow", "easee"}
Expand Down
5 changes: 5 additions & 0 deletions go/internal/control/dispatch.go
Original file line number Diff line number Diff line change
Expand Up @@ -407,6 +407,9 @@ type State struct {
// dispatchMeterAt is the UpdatedAt of the last site-meter sample the
// battery dispatch acted on. See siteMeterHeld.
dispatchMeterAt time.Time
// meterFreeze finds a site meter that repeats one reading while FTW's
// orders move. See ObserveSiteMeterFreeze.
meterFreeze meterFreeze

// Slew + holdoff
SlewRateW float64
Expand Down Expand Up @@ -1459,6 +1462,8 @@ func ComputeDispatch(
rawGridW = siteMeter.SmoothedW
}
meterHeld := state.siteMeterHeld(siteMeter)
// A repeat that ignores FTW's own move is no new sample either.
meterHeld = meterHeld || state.siteMeterRepeatsAfterMove(siteMeter)
// Live EV/V2X charger readings override the manual slider on each tick —
// hardware truth beats guesses. Positive V2X is a vehicle charging load;
// negative V2X is kept separate so the default controller does not
Expand Down