Repository navigation
Operations Guide
- Start the application and confirm robot connection status.
- Import or sync
.robplans:- Automatic via configured USB path.
- Manual via the Settings import action.
- Load a pallet plan in the main view.
- Verify package height, weight, start layer, clamp state, label invert, and scanner overrides.
- Confirm the XML-RPC server is running.
- Let the robot poll
get_status()orUR_GetStatus()untilready == true. - Run production and monitor scanner/safety indicators.
- Stop the RPC server when done.
flowchart TD
Start["Start Application"] --> Check["Check Robot Connection"]
Check --> Import["Import or Sync .rob Plans"]
Import --> Load["Load Pallet Plan"]
Load --> Verify["Verify Runtime Settings"]
Verify --> Serve["Start XML-RPC Server"]
Serve --> Ready["Robot Polls get_status"]
Ready --> Run["Run Production and Monitor Status"]
Run --> Stop["Stop RPC Server"]
| File or directory | Purpose |
|---|---|
settings.json |
Runtime configuration. |
paletten.db |
SQLite palette database, unless database.path points elsewhere. |
logs/ |
Per-launch application and server log files. |
| Configured USB path | Source for .rob imports and offline update packages. |
get_status() and UR_GetStatus() return a struct containing ready, file, and message.
ready == false
message == "XML-RPC listening; palette data not ready"
means the HTTP/XML-RPC socket is reachable, but no palette data has been loaded. Operational methods return an XML-RPC fault with code 503 until readiness is true.
The application connects to the Universal Robots Dashboard Server at robot.ip:robot.dashboard_port, default 192.168.0.1:29999.
| Application function | Dashboard command |
|---|---|
| Robot mode | robotmode |
| Safety mode/status | safetymode |
| Program state | programState |
| Polyscope version | PolyscopeVersion |
| Serial number | get serial number |
| Loaded program | get loaded program |
| Load program | load <path> |
| Play | play |
| Pause | pause |
| Stop | stop |
| Power on/off |
power on, power off
|
| Brake release | brake release |
| Safety recovery |
close safety popup, unlock protective stop, restart safety
|
Dashboard connection failure during startup is non-fatal. The HMI can still run and XML-RPC can still serve loaded palette data.
| Channel | File name |
|---|---|
| Application | multipack_parser_<yyyymmdd_HHMMSS>.log |
| XML-RPC/server | server_<yyyymmdd_HHMMSS>.log |
Log files are UTF-8. Each channel rotates at 5 MB with up to 5 backups for the current launch. If logs/ cannot be used, logging falls back to the user home directory.
--verbose enables debug-level application logging for the current run. The server log channel always records debug-level server entries.
- Active palette and palette-switch XML-RPC methods are available.
- Scanner override values can be set in the HMI and read by XML-RPC.
- The
UR_SetZwischenLageLegenmethod exposes intermediate-layer state. - Palette methods return sentinel values such as
404,503,0, or1; see XML-RPC API.
- Safety monitor checks robot safety state periodically.
- Reduced mode warning repeats at a rate-limited interval.
- Non-normal safety states trigger alarm behavior.
- Scanner warning playback is rate-limited to avoid rapid repeats.
flowchart TD
Poll["Safety Poll"] --> Unknown{"Status Unknown"}
Unknown -- "Yes" --> Reset["Reset Alarm and Warning State"]
Unknown -- "No" --> Reduced{"Reduced Mode"}
Reduced -- "Yes" --> Warn["Play Warning"]
Reduced -- "No" --> Normal{"Normal State"}
Normal -- "Yes" --> Clear["Clear Alarm"]
Normal -- "No" --> Alarm["Play Alarm and Raise Alert"]
<- Previous: Getting Started | Home | Next: Configuration ->