Untested – not built or flashed; I didn't want to flash the EC on my work laptop.

A single full scan in which any hub board ID channel misreads cuts input deck power immediately, while power-on is already debounced by INPUT_MODULE_POWER_ON_DELAY. On affected units this power-cycles the keyboard and touchpad every few seconds in Auto mode.

Require the deck to read as not fully populated for more than INPUT_MODULE_DISCON_DEBOUNCE before powering it off.

Evidence (Laptop 16, Ryzen AI 7 350, BIOS 04.01, EC tulip-4.0.1-9b2a0b1)

  • 639 keyboard USB disconnects in 24 h in Auto mode. 87% were back within 1 s, consistent with one bad scan followed by the 300 ms power-on delay.
  • Reproducible at runtime: framework_tool --inputdeck-mode auto → drops within seconds; --inputdeck-mode on → stable immediately.
  • framework_tool --inputdeck reports the same modules (Pos 1 FullWidth, touchpad present) even in snapshots taken while the deck state is Disconnected/TurningOn.
  • Always on (BIOS or --inputdeck-mode on) works around it.

Possibly related: https://community.frame.work/t/framework-16-keyboard-numpad-and-touchpad-disconnect-stop-working/67132/18

Note: I used AI to help write the commit message and analysis.

BRANCH=fwk-tulip-29169
BUG=input deck power-cycles every few seconds in Auto mode
TEST=none; not built or flashed (work machine). Needs verification on hardware: Auto mode should show no keyboard USB disconnects, and removing a module should still power the deck off.

A single full scan in which any hub board ID channel misreads cuts
input deck power immediately, while power-on is already debounced by
INPUT_MODULE_POWER_ON_DELAY. On affected units this power-cycles the
keyboard and touchpad every few seconds in Auto mode.

Require the deck to read as not fully populated for more than
INPUT_MODULE_DISCON_DEBOUNCE before powering it off.

BRANCH=fwk-tulip-29169
BUG=input deck power-cycles every few seconds in Auto mode
TEST=none; not built or flashed (work machine). Needs verification on
hardware: Auto mode should show no keyboard USB disconnects, and
removing a module should still power the deck off.

Signed-off-by: Arthur <avanhoorebeke@gmail.com>
@arthurvanh
arthurvanh marked this pull request as ready for review October 30, 2026 07:04